Item Name | Relay Electromagnet |
INC Code | 32512 |
Federal Supply Group (FSG) | 59 Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5945 Relays and Solenoids |
National Item Identification Number (NIIN) | 00-825-5648 (008255648) |
NCB Code | USA (00) |
Part Number | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
231B244AD12 | ward leonard electric company inc | relay electromagnet | Avl | RFQ |
231B244AD12 | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
231B244AD12 | rockwell collins inc | relay electromagnet | Avl | RFQ |
231B244AD12 | general electric company | relay electromagnet | Avl | RFQ |
231B244AFP14 | rockwell collins inc | relay electromagnet | Avl | RFQ |
231B244AFP14 | general electric company | relay electromagnet | Avl | RFQ |
231B244AFP14 | ward leonard electric company inc | relay electromagnet | Avl | RFQ |
231B244AFP14 | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
231B244AFPC14 | ward leonard electric company inc | relay electromagnet | Avl | RFQ |
231B244AFPC14 | general electric company | relay electromagnet | Avl | RFQ |
2412L9DN | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
402-0300-00 | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
402-0300-00 | general electric company | relay electromagnet | Avl | RFQ |
402-0300-00 | rockwell collins inc | relay electromagnet | Avl | RFQ |
402-0300-000 | rockwell collins inc | relay electromagnet | Avl | RFQ |
402-0300-000 | general electric company | relay electromagnet | Avl | RFQ |
402-0300-000 | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
7012L9DN | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
DEY12NI | tyco electronics agastat relays | relay electromagnet | Avl | RFQ |
DEY12NI | rockwell collins inc | relay electromagnet | Avl | RFQ |
DEY12NI | harvard industries inc | relay electromagnet | Avl | RFQ |
DEY12NI | general electric company | relay electromagnet | Avl | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.250 INCHES MAXIMUM |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 1.750 INCHES NOMINAL SECOND MOUNTING FACILITY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.880 INCHES NOMINAL FIRST MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 4.520 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
ADZC | ENVIRONMENTAL PROTECTION | DUSTPROOF |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.199 INCHES NOMINAL FIRST MOUNTING FACILITY |
AFJN | FRAGILITY FACTOR | MODERATELY RUGGED |
AJSS | FREQUENCY IN HERTZ | 60.0 NOMINAL |
AKDX | WINDING QUANTITY | 1 |
AKSL | PURPOSE FOR WHICH DESIGNED | GENERAL |
APCN | COIL QUANTITY | 1 |
APNP | DUTY TYPE | CONTINUOUS |
APNQ | ARC QUENCHING METHOD | AIR |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 THREADED HOLE SECOND MOUNTING FACILITY |
BBRG | STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR FIRST MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 2 POLE,DOUBLE THROW,ONE POSITION MOMENTARY |
CRXH | TIME DELAY | 5.00 SECONDS MINIMUM ADJUSTABLE RELEASE TIME AND 50.00 SECONDS MAXIMUM ADJUSTABLE RELEASE TIME |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 230.0 VOLTS AC 25 DEG CELSIUS SINGLE WINDING |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 240.0 AC AND 30.0 DC |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND MOUNTING FACILITY |
TTQY | TERMINAL TYPE AND QUANTITY | 8 SCREW ALL FUNCTIONS |
AAJD | THREAD CLASS | 2B SECOND MOUNTING FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND MOUNTING FACILITY |
ABMK | OVERALL WIDTH | 3.090 INCHES MAXIMUM |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.500 INCHES NOMINAL SECOND MOUNTING FACILITY |
AEBW | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO HEIGHT | 0.750 INCHES MINIMUM FIRST MOUNTING FACILITY AND 1.500 INCHES MAXIMUM FIRST MOUNTING FACILITY |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 6 UNTHREADED HOLE FIRST MOUNTING FACILITY |
CBME | CUBIC MEASURE | 45.392 CUBIC INCHES |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND MOUNTING FACILITY |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES SECOND MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SECOND MOUNTING FACILITY |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 10.0 AMPERES AC RESISTIVE LOAD AND 15.0 AMPERES DC RESISTIVE LOAD |
CWJB | ENERGIZING ELEMENT POWER RATING | 8.0 WATTS |
Relevant Components for NSN - 5945-00-825-5648, 5945008255648 | ||||
5977-01-443-2085 (5977014432085) | 5905-01-680-4188 (5905016804188) | 5905-00-619-3482 (5905006193482) | 5905-01-551-4002 (5905015514002) | |
5999-01-165-6458 (5999011656458) | 5905-00-974-6217 (5905009746217) | 5980-01-304-1377 (5980013041377) | 5935-00-803-3215 (5935008033215) | |
5930-01-252-2902 (5930012522902) | 5998-00-230-4631 (5998002304631) | 5935-00-067-5905 (5935000675905) | 5930-01-238-4094 (5930012384094) | |
AS9120B and ISO 9001:2015 |
|
Aviation Suppliers Association Member |
|
FAA AC 0056B Accredited |
|
AS 6081:2012 Certification |
|
ESD S20.20-2014 Certification |